APC SBP16KRMP4U-HW service bypass panel for Symmetra LX 200/208/240 V systems with L14-30R and L5-20R outlets
Out of Stock

APC SBP16KRMP4U-HW Service Bypass Panel 200/208/240V | Rack Mount

APC

MPN: SBP16KRMP4U-HW

$1,711.94$2,125.00
Contact Us for Availability
Free shipping on orders over $500
Authorized Dealer — Full manufacturer warranty

Key Features

  • Service bypass panel for APC Symmetra LX UPS systems
  • Supports 200/208/240 V input
  • Rated for 4-16 kVA Symmetra LX configurations
  • Includes one L14-30R outlet
  • Includes three L5-20R outlets
  • Includes one 100 A hardwire connection
  • Designed for maintenance continuity in critical power environments
  • Maintain uptime during UPS service with a dedicated bypass path for Symmetra LX systems
Maintain uptime when UPS service cannot wait. The APC SBP16KRMP4U-HW service bypass panel is built for Symmetra LX environments running 200/208/240 V at 4-16 kVA, giving infrastructure teams a direct path to keep connected loads energized during maintenance or replacement work. Its outlet mix is designed for practical deployment: one L14-30R, three L5-20R, and one 100 A hardwire connection support a range of downstream equipment and installation requirements. That flexibility matters in real data center and edge environments where load profiles rarely match a single receptacle type. For teams responsible for availability, the value is straightforward: isolate the UPS without taking the protected load down. That reduces maintenance risk, shortens service windows, and helps preserve operational continuity in environments where even brief interruptions carry cost. This panel is a purpose-built accessory for Symmetra LX power architectures, not a generic distribution device. It is intended for organizations that need a dependable bypass path, clean service procedures, and the confidence that critical systems can stay online while power infrastructure is being worked on.

Ideal For

  • Bypass a Symmetra LX UPS during scheduled maintenance without interrupting connected loads
  • Support replacement work in a data center power chain where uptime must be preserved
  • Provide a controlled service path for mixed receptacle and hardwired equipment
  • Reduce outage exposure during UPS inspection, repair, or battery-related service

Why This Product

  • 1Purpose-built for Symmetra LX service continuity
  • 2Supports mixed receptacle and hardwire connections
  • 3Rated for 4-16 kVA power environments
  • 4Designed to keep loads energized during UPS maintenance